90 answers for technicians, workshops, companies and walk-in customers β buying parts, and the common AC and refrigeration questions behind them. Supplied from Musaffah to every emirate in the UAE.
90 answers
We are in the Musaffah Industrial Area of Abu Dhabi, the main trade zone for AC and automotive parts. Walk-in customers are welcome during opening hours, and you can call or WhatsApp us for directions.
We are open all days from 8:00 AM to 9:00 PM.
Yes. We are a walk-in shop. Bring the old part with you if you have it, and our team will match it from stock.
No. We serve both retail and wholesale customers. Individual car owners and homeowners buy single pieces, and companies buy in bulk.
Yes. There is no minimum order for retail customers. Wholesale pricing applies to larger quantities.
Send us a photo or the model number on WhatsApp, call the shop, or add items to the quote list on this website and send it in one go. We reply with price and availability.
Both. Most in-stock items can be collected the same day from Musaffah, and we deliver across Abu Dhabi, Dubai and the other Emirates. Contact us to confirm delivery for your order.
Yes, and this is the most common way customers buy from us. Send a photo of the part or the unit on WhatsApp and our team will identify it, confirm whether it is in stock and quote you.
For AC parts: the nameplate on the unit or the old part, showing model, tonnage, voltage and refrigerant type. For car parts: the make, model and year of the vehicle. Photos of the old part from two angles also help.
Yes. Our team has been identifying parts for over 20 years and can usually confirm an exact or compatible match within minutes during working hours.
Yes. Use the search on our Products page, or send the number to us directly and we will check stock for you.
We will offer a tested, compatible OEM-grade alternative where one exists, or source the original for you. We always tell you which of the two you are getting.
Yes, and we recommend it. Message us on WhatsApp with the part details and we will confirm availability before you make the trip.
Our Products page lists over 1,000 product lines, and we keep more than 10,000 parts in stock across 30+ categories. Stock changes daily, so message us to confirm current availability for a specific item.
Rotary, scroll and reciprocating compressors. Rotary units for split and window AC are our fastest-moving line, with scroll compressors for ducted, package and light commercial systems.
Yes, in the common tonnages from roughly 1.0 to 3.0 ton, normally available for same-day collection.
Yes. We carry 220V single-phase and 380V three-phase models. Check the old compressor label so we can match the supply correctly.
Yes. Whenever the refrigerant circuit is opened, and always with a compressor change, the drier should be replaced. Moisture left in the system is a common cause of repeat compressor failure.
Both. We stock genuine branded compressors as well as OEM-grade aftermarket options, and we tell you clearly which one you are buying so you can decide on price or warranty.
Send a WhatsApp photo of the nameplate on the old compressor. We match the tonnage, voltage, refrigerant and terminal layout from that.
R410A, R32, R134a, R407C, R404A and R22 in the commonly used cylinder sizes.
The refrigerant type is printed on the outdoor unit nameplate. Send us a photo and we will confirm the correct gas and the quantity you need.
Both are fine. Technicians regularly buy one cylinder at a time, and companies buy by the pallet at wholesale rates.
Yes. For large or pallet quantities, contact us in advance so we can reserve stock for you.
We stock the common disposable and refillable cylinder sizes used in the UAE market. Tell us the gas and quantity and we will confirm what is available.
We supply R22 for older installations that are still in service, subject to availability and the regulations in force at the time.
Yes. We stock R134a for most vehicles and R1234yf for newer models, along with PAG compressor oils.
Yes. Automotive AC is a major part of our business: compressors, condensers, evaporators, receiver driers, expansion valves, hoses and fittings.
Most Japanese, Korean, American and European models, including Toyota, Nissan, Mitsubishi, Honda, Hyundai, Kia, Ford and Chevrolet. Send the make, model and year to confirm.
The make, model and year of the vehicle. A photo of the old part, and the chassis or VIN number where available, makes the match faster and more accurate.
We stock complete compressor assemblies with clutch and pulley, and also supply clutch coils, pulleys and bearings separately.
Yes, PAG compressor oils in the common grades along with system flush, so the job can be completed in one visit.
Yes. Workshops and garages are among our regular customers and receive wholesale rates on fast-moving items.
Yes, refrigeration-grade soft copper tubing in the common sizes, sold by the full roll or in cut lengths.
Yes, pre-insulated pair coils in the size combinations normally used for split AC installation.
Match the microfarad (Β΅F) rating and the voltage printed on the old capacitor. Send us a photo of the label and we will give you the exact equivalent.
Match the voltage, wattage, speed, shaft size and direction of rotation, all of which are printed on the old motor label. We also supply the matching run capacitor.
Yes. Manifold gauge sets, charging hoses, vacuum pumps, flaring and swaging tools, leak detectors and scales are all in stock.
Yes, pipe insulation, brass flare nuts, unions, tees, reducers and related accessories.
Yes. Maintenance companies, contractors, facility management firms, workshops and resellers receive volume-based wholesale rates.
Yes. Send us your requirement list and we will issue a formal quotation with part descriptions and prices.
Yes, we support LPO-based purchasing for corporate procurement teams. Contact us to set this up.
Yes. We supply maintenance and FM companies on an ongoing basis and can hold fast-moving items for regular buyers. Talk to us about your usage and we will plan stock around it.
Payment and account terms are arranged case by case. Please contact us with your company details to discuss.
Yes. We supply other retailers and traders at wholesale rates, particularly on refrigerant, copper and fast-moving spares.
Please contact us to confirm the payment options currently accepted for your order type, whether retail or company purchase.
Warranty depends on the brand and the item. Ask our team at the time of purchase and we will tell you exactly what applies to the part you are buying.
Contact us with your invoice and the details of the item. Electrical items and parts that have been installed may be treated differently, so please check with us before fitting.
Most in-stock items are ready for same-day collection from Musaffah. For delivery, contact us and we will confirm the schedule for your area.
Our regular delivery network covers the UAE. For orders outside the country, contact us with the details and we will advise what is possible.
No. The website shows our main lines, but we source any air-conditioning, refrigeration or car AC part. If you cannot see it, send us the details on WhatsApp and we will find it.
Yes. Through our supplier network we source parts that are not on the shelf, including less common and older items. Tell us what you need and we will confirm availability and timing.
Yes. We supply genuine and compatible parts for most residential and commercial AC brands sold in the UAE. Send the unit model number and the part you need and we will match it.
Yes. Compressors, filter driers, valves, contactors, fan motors and refrigerant for cold rooms, display chillers and light commercial systems. Share the equipment details for a quote.
Yes. Many window-unit and older-model parts are still in stock or interchangeable with current items. Send a photo of the old part and we will confirm.
Yes. We supply customers across the UAE. Order on WhatsApp, and we will arrange delivery to Dubai, Sharjah, Al Ain, the Northern Emirates or anywhere else in the country.
The usual causes are low refrigerant from a leak, a dirty condenser or evaporator coil, a failed run capacitor, a weak compressor, or a blocked filter. Check airflow and coils first, then pressures.
Common causes are a shorted or weak capacitor, a compressor drawing high current because the condenser is dirty or the fan has failed, low supply voltage, or a compressor winding fault. Check the outdoor fan and capacitor before condemning the compressor.
Ice usually means low refrigerant, restricted airflow from a dirty filter or coil, or a failed indoor fan. Switch the unit off to defrost, clear the airflow problem, then check the charge and look for a leak.
Most often a blocked condensate drain, an iced coil that is now thawing, a drain tray that has cracked, or a unit installed without enough slope towards the drain.
A humming sound with no start is the classic sign of a failed run capacitor. Test and replace the capacitor first; if the compressor still fails to start, the motor windings or the contactor may be at fault.
Poor heat rejection: a dirty condenser coil, a failed condenser fan motor, an overcharged or undercharged system, or high ambient temperature combined with restricted airflow. Fix the airflow and check the charge before replacing the compressor.
Check the fan capacitor first, then the fan motor itself, the contactor and the wiring. A motor that spins freely by hand but will not start is usually a capacitor; a seized or noisy motor needs replacement.
Usually mould or bacteria on the evaporator coil and in the drain tray. Cleaning the coil and flushing the drain normally solves it.
The most common causes are low refrigerant from a leak, the compressor clutch not engaging, a failed condenser fan, a blocked condenser or a failed compressor. A pressure check with gauges points to the cause quickly.
Typical reasons are low refrigerant (the low-pressure switch cuts the clutch), a burnt clutch coil, a blown fuse or relay, or a worn clutch gap. Confirm system pressure first, then test the clutch coil.
With clean coils, correct charge and a healthy capacitor, a compressor commonly lasts 10 to 15 years. Most early failures are caused by dirty condensers, low or wrong refrigerant, moisture in the system, or repeated starting on a weak capacitor.
If the unit is over 12β15 years old, uses R22, or needs a compressor plus a coil, replacement is often the better value. For a single failed part on a younger unit, repair is usually worthwhile. We will give you the part price so you can compare.
R410A runs at much higher pressures than R22 and uses POE oil instead of mineral oil. They are not interchangeable: an R22 compressor cannot run on R410A and the gauges, hoses and driers must be rated for the gas in use.
Small top-ups are common practice provided R410A is charged as a liquid from the cylinder. For a large loss, find and repair the leak, evacuate the system and recharge to the nameplate weight for reliable performance.
No. Mixing refrigerants changes the pressures and the oil compatibility, damages the compressor and makes the gas impossible to recover correctly. Always use the refrigerant on the nameplate.
R32 is classed A2L, meaning mildly flammable. It is safe when handled with A2L-rated tools, no open flames or sparks nearby, good ventilation and correct charge quantities. Use gauges and hoses rated for R32.
R1234yf is the newer, low-GWP refrigerant fitted to most cars from the mid-2010s. The two are not interchangeable: they use different service ports and the system must be charged with the type it was designed for.
The standard charge is printed on the outdoor unit nameplate and is correct for a set pipe length, typically 5 to 7.5 metres. Longer pipe runs need extra gas per metre as stated in the manufacturer's data.
Evacuation removes air and moisture. Moisture reacts with the refrigerant and oil to form acids that corrode the compressor, and non-condensable gases raise head pressure. Pull down to around 500 microns and confirm it holds before charging.
R22 systems use mineral or alkylbenzene oil. R410A, R407C and R404A use POE oil. Car AC systems on R134a and R1234yf use PAG oil of the grade specified for that compressor. Never mix oil types.
One ton of cooling equals 12,000 BTU per hour, or roughly 3.5 kW. A 1.5-ton unit is 18,000 BTU/h and a 2-ton unit is 24,000 BTU/h.
A rough guide in UAE conditions is one ton for every 12 to 15 square metres, with more capacity for sun-facing rooms, large glass areas or high ceilings. A technician should confirm the load before buying.
Rotary compressors are compact and common in split and window units. Scroll compressors are quieter and more efficient, used in ducted, package and commercial systems. Reciprocating compressors are the traditional piston design, still common in refrigeration.
No. Inverter compressors are DC motors driven by a control board and are not interchangeable with fixed-speed compressors. The replacement must match the original type and be compatible with the unit's board.
It provides the phase shift a single-phase motor needs to start and run efficiently. A weak capacitor causes hard starting, humming, overheating and high current draw in compressors and fan motors.
The expansion valve meters refrigerant into the evaporator. Replace it when it sticks open or closed, shows erratic superheat, or is contaminated after a compressor burn-out.
In the direction of refrigerant flow, following the arrow printed on the drier body. On a liquid-line drier the arrow points from the condenser towards the expansion device.
Commonly 1/4" and 3/8" for 1 to 1.5 ton units, 1/4" and 1/2" for 2 ton, and 3/8" and 5/8" for 2.5 to 3 ton. Always check the manufacturer's connection sizes for the specific model.
Because of the heat and dust, every three to four months is common for heavily used units, and at minimum a full service before summer. Filters should be cleaned monthly in peak season.
Switch off the power, remove loose debris, apply a coil cleaner, then rinse from the inside out with low-pressure water so the fins are not flattened. Straighten bent fins with a fin comb.
The suction line carries cold gas back to the compressor. Without insulation it sweats, drips and loses cooling capacity, and the compressor can receive warmer gas than designed.
Pull the system down to around 500 microns, isolate the pump and watch the gauge. If it holds for 15 to 30 minutes without rising, the system is dry and tight; a steady rise indicates moisture or a leak.
We strongly recommend it. Refrigerant handling needs recovery equipment, gauges and training, and incorrect charging is the most common cause of early compressor failure.
The nameplate lists the model number, cooling capacity (BTU/h or kW), refrigerant type and charge, voltage and phase, and rated current. A photo of it gives us everything needed to match most parts.